EN
040 28573297 Request a quote

Glossary

Screed glossary from A to Z

The key technical terms around screed, briefly explained. Next to each term is the German word, which helps on projects in Germany.

Bonded screed Verbundestrich
Screed that is firmly bonded to the load-bearing substrate by a bonding bridge. See Industrial and commercial screed.
Cement screed Zementestrich
Screed with cement as binder, code CT. Moisture-resistant and universally usable. See Cement screed.
CM test (carbide method) CM-Messung
Measuring residual moisture with the calcium carbide method. A screed sample reacts with carbide in a pressure bottle, and the pressure shows the water content in CM-%.
Compressive strength Druckfestigkeit
The screed's resistance to compression, given as class C, for example C25 for 25 N/mm².
Contraction joint (dummy joint) Scheinfuge
A cut in the upper part of the screed that gathers shrinkage cracks at a planned place. It is closed later with a force-transmitting fill.
DIN 18202 (tolerances) DIN 18202
Standard for tolerances in building. It sets how flat a screed area must be.
DIN 18560 (screeds) DIN 18560
German standard for screeds in building. Part 2 covers floating screeds and heated screeds, part 3 bonded screeds, part 4 screeds on a separating layer, part 7 heavy-duty screeds.
Dry screed Trockenestrich
Screed made of boards that are laid dry. No drying time, low weight.
Drying heating Belegreifheizen
Deliberate heating of a heated screed to speed up drying until it is ready for covering. Follows function heating.
Edge insulation strip Randdämmstreifen
Strip of soft insulation material that separates the screed from walls, columns and door frames. Prevents sound bridges and takes up movement.
Fast-drying screed Schnellestrich
Screed with rapid-hardening cement or a drying accelerator, ready for covering after days instead of weeks. See Fast-drying screed.
Flatness Ebenheit
Permitted deviation of the surface from a plane, measured with straightedge and measuring wedge to DIN 18202.
Flexural strength Biegezugfestigkeit
The screed's resistance to bending, given as class F, for example F4 for 4 N/mm². For floating screed it is the decisive figure.
Floating screed Schwimmender Estrich
Screed on an insulation layer with no firm connection to slab and walls. See Screed on insulation.
Function heating Funktionsheizen
First heating of a heated screed under DIN EN 1264-4: 3 days at 20 to 25 °C, then 4 days at the maximum design temperature.
Heated screed Heizestrich
Floating screed with underfloor heating. In type A the heating pipes lie in the screed. See Heated screed.
Heating protocol Aufheizprotokoll
Document that records the heating of a heated screed day by day, with flow temperature and signatures. The timeline planner creates a template.
Impact sound insulation Trittschalldämmung
Insulation layer that does not pass footfall noise on into the slab. Effective only if the screed is separated all round by the edge insulation strip.
Insulation layer Dämmschicht
Layer of thermal and impact sound insulation under the floating screed.
Levelling fill Ausgleichsschüttung
Bound fill that embeds pipes and cables on the structural slab and creates a flat surface for the insulation.
Metre mark (datum line) Meterriss
A mark on the wall exactly one metre above the planned top of the finished floor. The reference height for all trades.
Movement joint Bewegungsfuge
A joint that separates the screed through its full thickness so that bays can move independently. Usual in door openings and on large heated areas.
Nominal thickness Nenndicke
The planned thickness of the screed. For heated screed type A it is measured over the heating pipe.
Pipe cover Rohrüberdeckung
Screed thickness over the heating pipe. At least 45 mm for cement screed CT-F4 is usual.
Readiness for covering Belegreife
The state in which the screed has dried far enough for the floor covering to be laid. It is proved with the CM test.
Residual moisture Restfeuchte
The share of water left in the screed. Limit values for readiness for covering: cement screed 2.0 CM-%, heated 1.8 CM-%.
Screed Estrich
A layer of mortar laid on a load-bearing substrate or on insulation. It levels heights, spreads loads and carries the floor covering.
Screed pump (pneumatic conveyor) Estrichpumpe
Machine that mixes screed mortar and conveys it with compressed air through a hose to the laying point. See Equipment.
Screeding (levelling) Abziehen
Levelling the fresh screed to the specified height with the straightedge. The height is set by the rotary laser or a gauge.
Separating layer Trennlage
Film between substrate or insulation and screed. It stops water from the mortar running down.
Strength class Festigkeitsklasse
Grading of the screed under DIN EN 13813, for example CT-C25-F4: cement screed with 25 N/mm² compressive strength and 4 N/mm² flexural strength.
Trowelling Glätten
Compacting and closing the screed surface with a trowel or power trowel.

Quote

Screed planned? Let's talk.

Tell us the area, screed type and desired date. You will receive a clear quotation.